Standards: | IEC / EN 60204-1; EN 60947-5-1; EN 60947-5-3; EN ISO 13849-1; IEC 61508; BG-GS-ET-14; BG-GS-ET-20 |
Start conditions: | Automatic or start button |
Feedback circuit available: | yes |
Start-up test: | AES ...5: no; AES ...6: yes |
Pull-in delay for automatic start: | adjustable 0.1 / 1.0 second |
Drop-out delay in case of "emergency stop": | < 50 ms |
Rated operating voltage Ue: | 24 VDC ± 15% |
Rated operating current Ie: | 0.2 A |
Rated insulation voltage Ui : | 250 V |
Rated impulse withstand voltage Uimp: | 4.8 kV |
Thermal test current Ithe: | 6 A |
Internal electronic fuse: | no |
Power consumption: | < 5 W |
Monitored inputs: | |
Cross-wire short detection: | selectable |
Wire breakage detection: | yes |
Earth connection detection: | yes |
Number of NC contacts: | convertible 1NC → 2NC |
Number of NO contacts: | convertible 1NO → 0NO |
Outputs: | |
Stop category 0: | 2 |
Stop category 1: | 0 |
Number of safety contacts: | 2 |
Number of auxiliary contacts: | 0 |
Number of signalling outputs: | 2 |
Switching capacity of the signalling outputs: | Y1-Y2 = 100 mA |
Switching capacity of the safety contacts: | min. 10 mA max. 6 A |
Utilisation category to EN 60947-5-1: | AC-15: 230 V / 3 A DC-13: 24 V / 2 A |
Max. fuse rating: | 6 A gG D-fuse |
Mechanical life: | 20 million operations |
LED display: | ISD |
Ambient conditions: | |
Operating temperature: | 0 °C ... +55 °C |
Storage and transport temperature: | −25 °C ... +70 °C |
Resistance to shock: | 30 g / 11 ms |
Resistance to vibration: | 10 ... 55 Hz, amplitude 0.35 mm |
Protection class: | Enclosure: IP40 Terminals: IP20 Clearance: IP54 |
Degree of pollution: | 2 |
Mounting: | Snaps onto standard DIN rail to EN 60715 |
Connection type: | Screw connection |
Min. cable section: | 0.25 mm² |
Max. cable section: | 2.5 mm², solid strand or multi-strand lead (including conductor ferrules) |
Tightening torque: | 0.6 Nm |
Max. cable length: | 1000 m of 0.75 mm² conductor |
The Safety Module AES 1235 is designed for monitoring BNS range magnetic safety sensors. It features two safety contacts with a STOP 0 configuration, ensuring a robust safety mechanism. Additionally, it provides two signaling outputs to enhance overall safety signaling capabilities.
The STOP 0 configuration signifies an immediate cessation of designated processes upon activation, aligning with high safety standards. The two signaling outputs further extend the module's utility by facilitating effective communication of safety status or triggering additional safety measures.
With its compact design and versatile compatibility with BNS range magnetic safety sensors, the AES 1235 is suitable for various industrial applications. Its primary function lies in augmenting safety measures by monitoring and responding to magnetic safety sensors' signals.
Delivery terms
We offer convenient and flexible delivery terms to all our customers. No matter where you are, we will ensure fast and reliable delivery of your order.
Basic delivery conditions:
- Geography of delivery: We deliver throughout UK. Regardless of your location, you can be sure that your order will be delivered as quickly as possible.
- Delivery time: delivery time depends on your location and the delivery method you choose. We offer various options, including express shipping, to make sure you receive your order as quickly as possible.
-
Delivery costs: Delivery costs are calculated individually depending on the weight, dimensions of the goods and the destination. We are committed to offering our customers competitive shipping prices.
-
Delivery methods: We work with leading logistics companies to ensure safe and timely delivery. You can choose the delivery method that is most convenient for you.
-
Order tracking: once your order has been placed, you will receive a tracking number so that you can know the status and location of your order at any time.
-
Additional services: we also offer insurance and packaging services to make sure your item arrives safely.
- Please provide an accurate delivery address when placing your order to avoid delays and delivery errors.
- Please note that customs duties and taxes on the destination country may apply depending on the situation. These costs are not included in the cost of the goods and delivery and must be paid separately.
We make every effort to make the delivery process as convenient and fast as possible for you. If you have any questions or need additional information, our support team is always ready to help you.