Sale of Euchner products with worldwide delivery. We have a complete catalog of products of this brand. If you didn’t find something on the site, leave a request. The manager will call you back and help. Our current product range covers more than 90 percent of your needs, no matter what sector you are from (automotive, financial services, chemicals, pharmaceuticals or mechanical engineering, ...)

Competitive Prices
Competitive Prices
Lowest prices among our industrial parts reseller competitors
Extensive Product Range
Extensive Product Range
Thousands of industrial components and numerous suppliers
Swift Delivery
Swift Delivery
Reliable delivery of industrial spare parts worldwide
Sale of any product from the catalog Euchner
Brand
Euchner
Model
ESM-BA301
Article
085613
Country
Germany
  • ESM-BA.. Usage up to category 4 according to EN ISO 13849-1
  • LED status indicators
  • 1-channel or 2-channel control
  • 3 redundant safety contacts
  • 1 auxiliary contact (monitoring contact)
  • Short circuit and earth fault/ground fault monitoring
Relay outputsThe outputs are electrically decoupled and of redundant design. Connection optionsBy using suitable wiring the following functions can be selected:
  • Relay start with automatic start or a start button.
  • Monitoring of downstream relays or contactors
  • Simultaneity monitoring to monitor safety components over time.
  • Relay start using a monitored start button.
  • Short circuit monitoring to detect short circuits between the connection cables and to shut down the outputs or prevent relay starting if necessary.
  • Earth fault/ground fault monitoring to detect short circuits between the connection cables and earth or ground and to shut down the outputs or prevent relay starting if necessary.
Auxiliary contactsThe relays in the series ESM-BA3.. are available with electrically separate normally closed contacts and auxiliary contacts. Connection terminalsOptionally, the ESM-BA... devices are also available as version with plug-in connection terminals. Dimension drawing Wiring diagram Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Housing material Polyamide PA6.6
Weight
Net 0,23 kg
Ambient temperature -15 ... 40 °C
Degree of protection IP20
Mechanical life
operating cycles 10 x 106
Contact material AgSnO2
Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
Connection Connection terminals
Length of control cable
With conductor cross-section 0.75mm2 1000 m
Safety contacts 13/14, 23/24, 33/34
Number of safety contacts 3
Auxiliary contacts 41/42
Number of auxiliary contacts 1
Electrical connection ratings
Operating voltage
AC/DC 24 V -10% ... +10%
Rated insulation voltage Ui
AC 250 V
Rated impulse withstand voltage Uimp
Leakage path/air gaps 4 kV
Overvoltage category according to IEC EN 60664-1 3
Reverse polarity protection
On version UB =24V DC
Rated supply frequency 50 ... 60 Hz
Power consumption
at 24 V DC 2,3 W
Degree of contamination (external, according to EN 60947-1) 2
Connection cross-section 0,14 ... 2,5 mm? Connection terminal (size)
Test voltage
Control system/contacts 2,5 kV
Control voltage
On S11 24 V 18,6 ... 26 V Start button
Control current
S11...S14 60 mA
LED indicator 2 status displays (green) for relays K1 and K2
Auxiliary contacts 41/42
Type of output
NC Relay contacts, floating
Utilization category according to EN 60947-5-1
AC-12 2A , 250V
DC-12 2A, 50V
Breaking capacity according to UL 2A, 250V AC / 2A, 24V DC per contact
Safety contacts 13/14, 23/24, 33/34
Type of output
NO Relay contacts, floating and positively driven (redundant)
Switching voltage
AC max.250 V
DC max.24 V
Switching current
at 24V min.5 mA
Cumulative current max.15 A For all contacts
Fusing
External contact fuses (safety circuit) according to IEC 60269-1 10A gG (T6A / F8A)
Utilization category according to EN 60947-5-1
AC-15 3A , 250V
DC-13 3A , 24V
AC-12 8A ohmic load, 250V
DC-12 8A ohmic load, 50V
Breaking capacity according to UL 8A 250V AC / 3A 24V DC per contact
Other
In compliance with EN 60439-1: 1999 + A1: 2004, EN 60947-1: 2007, EN 60947-5-1: 2004, EN 60947-7-1: 2002, EN 61000-6-2: 2005, EN 61000-6-3: 2007, EN ISO 13849-1: 2015, EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015, EN 60204-1: 2007
Reliability values according to EN ISO 13849-1
Performance Level PL e
Category 4
PFHD 1.2 x 10-8
Number of switching cycles
? 1 A at 24 V DC max.350000 1/Jahr
? 2 A at 24 V DC max.100000 1/Jahr
? 0.1 A at 24 V DC max.500000 1/Jahr
Mission time 20 y
Euchner Safety Relay

Delivery terms

We offer convenient and flexible delivery terms to all our customers. No matter where you are, we will ensure fast and reliable delivery of your order.

Basic delivery conditions:

  • Geography of delivery: We deliver throughout UK. Regardless of your location, you can be sure that your order will be delivered as quickly as possible.
  • Delivery time: delivery time depends on your location and the delivery method you choose. We offer various options, including express shipping, to make sure you receive your order as quickly as possible.
  • Delivery costs: Delivery costs are calculated individually depending on the weight, dimensions of the goods and the destination. We are committed to offering our customers competitive shipping prices.
  • Delivery methods: We work with leading logistics companies to ensure safe and timely delivery. You can choose the delivery method that is most convenient for you.
  • Order tracking: once your order has been placed, you will receive a tracking number so that you can know the status and location of your order at any time.
  • Additional services: we also offer insurance and packaging services to make sure your item arrives safely.
Important information:
- Please provide an accurate delivery address when placing your order to avoid delays and delivery errors.
- Please note that customs duties and taxes on the destination country may apply depending on the situation. These costs are not included in the cost of the goods and delivery and must be paid separately.

We make every effort to make the delivery process as convenient and fast as possible for you. If you have any questions or need additional information, our support team is always ready to help you.