- Safety switch with guard locking and integrated evaluation electronics
- Short circuit monitoring
- Two safety outputs (semiconductor outputs)
- Bistable guard locking
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)
CTP?LBI | Guard locking operated by means of input signal. |
- persons from unintentionally locking themselves inside if the safety door is open in case of a power failure or if the machine is switched off.
- the deactivation of the activated guard locking in case of a power failure.
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
1 | IMP | Operating voltage of guard locking solenoid 24 V DC | WH | |
2 | UB | Operating voltage of AP electronics 24 V DC | BN | |
3 | FO1A | Safety output, channel 1 | GN | |
4 | FO1B | Safety output, channel 2 | YE | |
5 | OI | Diagnostic output | GY | |
6 | OD | Door monitoring output | PK | |
7 | OL | Guard locking monitoring output | BU | |
8 | 0 V UB | Control input of guard locking solenoid, 0 V | RD |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M12, 8-pin |
Approach speed | 20 m/min |
Guard locking principle | BiState |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 5 N |
Extraction force | 10 N |
Actuating force | 8 N |
Overtravel | 5 mm |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB (IMP=HIGH) | 440 mA |
IUB (IMP=LOW) | 40 mA |
IIMP (IMP=HIGH) | 20 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Fusing | |
External (operating voltage UB) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 1,7 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Control voltage | |
UIMP (HIGH) | 15 ... 24 V |
UIMP (LOW) | 0 ... 5 V |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
Low U(FO1A) / U(FO1B) | 0 ... 1 V DC |
High U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OL | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Guard lock monitoring | |
Mission time | 20 y |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10 -9 |
Guard locking control | |
Mission time | 20 y |
Category | B |
Performance Level | PL b |
PFHD | 2.1 x 10 -9 |
Explore the CTP-LBI-AP-U-HA-AZ-SA-127798 127798 industrial spare part, meticulously engineered for performance and reliability. This industrial spare part is crucial for ensuring your machinery operates smoothly and efficiently. With CTP-LBI-AP-U-HA-AZ-SA-127798 127798, you receive top-notch industrial spare parts designed for durability and optimal function.
The CTP-LBI-AP-U-HA-AZ-SA-127798 127798 replacement component ensures that your machinery will operate more efficiently, cutting downtime and preserving output. These replacement components provide unmatched durability and dependability since they are made to endure the demands of industrial operation. You may quickly get the parts you need by ordering your CTP-LBI-AP-U-HA-AZ-SA-127798 127798 spare part online and having it delivered to you.
A comprehensive selection of industrial spare parts suitable for different models and applications is provided by Euchner. In order to keep your equipment operating at peak efficiency, Euchner offers high-quality replacement parts that can be used for maintenance or to replace worn-out components.
You may rely on Euchner as your reliable supplier for high-performance industrial spare parts. To get the necessary spare parts, place an online order or stop by our store. You can invest in efficiency and quality for your industrial machines by using CTP-LBI-AP-U-HA-AZ-SA-127798 127798. Our industrial spare parts are made to the highest specifications and provide dependable solutions for all of your equipment requirements.
Euchner ensures that you find the right spare parts next to you or available online. Order now and experience the difference in equipment performance with Euchner CTP-LBI-AP-U-HA-AZ-SA-127798 127798. Invest in industrial spare parts that provide dependable service and keep your operations running smoothly.
Delivery terms
We offer convenient and flexible delivery terms to all our customers. No matter where you are, we will ensure fast and reliable delivery of your order.
Basic delivery conditions:
- Geography of delivery: We deliver throughout UK. Regardless of your location, you can be sure that your order will be delivered as quickly as possible.
- Delivery time: delivery time depends on your location and the delivery method you choose. We offer various options, including express shipping, to make sure you receive your order as quickly as possible.
-
Delivery costs: Delivery costs are calculated individually depending on the weight, dimensions of the goods and the destination. We are committed to offering our customers competitive shipping prices.
-
Delivery methods: We work with leading logistics companies to ensure safe and timely delivery. You can choose the delivery method that is most convenient for you.
-
Order tracking: once your order has been placed, you will receive a tracking number so that you can know the status and location of your order at any time.
-
Additional services: we also offer insurance and packaging services to make sure your item arrives safely.
- Please provide an accurate delivery address when placing your order to avoid delays and delivery errors.
- Please note that customs duties and taxes on the destination country may apply depending on the situation. These costs are not included in the cost of the goods and delivery and must be paid separately.
We make every effort to make the delivery process as convenient and fast as possible for you. If you have any questions or need additional information, our support team is always ready to help you.