Sale of Euchner products with worldwide delivery. We have a complete catalog of products of this brand. If you didn’t find something on the site, leave a request. The manager will call you back and help. Our current product range covers more than 90 percent of your needs, no matter what sector you are from (automotive, financial services, chemicals, pharmaceuticals or mechanical engineering, ...)

Competitive Prices
Competitive Prices
Lowest prices among our industrial parts reseller competitors
Extensive Product Range
Extensive Product Range
Thousands of industrial components and numerous suppliers
Swift Delivery
Swift Delivery
Reliable delivery of industrial spare parts worldwide
Sale of any product from the catalog Euchner
Brand
Euchner
Model
CEM-I2-AR-U-C40-SH-124937
Article
124937
Country
Germany
  • Safety switches with guard locking for process protection and integrated evaluation electronics
  • Solenoid with locking force 600 N
  • Adhesive-force adjustment in 3 levels
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1 for door position monitoring
  • With plug connector M23
  • Unicode
  • Door monitoring output
Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Guard locking type
CEM?I2Guard locking actuated by energy ON and released by energy OFF.
Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connecting cable
1 IMP Control voltage, guard locking solenoid, 24 V DC VT
2 FI1A Enable input for channel 1 RD
3 FI1B Enable input for channel 2 GY
4 FO1A Safety output, channel 1 RD/BU
5 FO1B Safety output, channel 2 GN
6 UB Operating voltage, 24 V DC BU
7 RST Reset input GY/PK
8 OT Door monitoring output GN/WH
9 OI Diagnostic output YE/WH
10 OL Guard locking monitoring output GY/WH
11 - n.c. BK
12 FE Function earth (must be connected to meet the EMC requirements) GN/YE
13 - n.c. PK
14 - n.c. BN/GY
15 - n.c. BN/YE
16 - n.c. BN/GN
17 - n.c. WH
18 - n.c. YE
19 0 V UB Operating voltage, 0 V BN
Material
Read head Plastic (PBT)
Solenoid Nickel-plated steel
Housing material Aluminum
Weight 0,64 kg
Ambient temperature -20 ... 55 °C
Degree of protection IP65/IP67
Resilience to vibration In acc. with EN 60947-5-3
Mechanical life
In case of use as door stop, and 1 Joule impact energy 1 x 106
Installation orientation Any
Tightening torque
Fixing screws 4 Nm
Ready delay 12 s
Connection Plug connector M23, 19-pin
Locking force Fmax
In axial direction 600 N
Adhesive force
adjustable 0, 30, 50 N
Electrical connection ratings
Operating voltage
DC 24 V -15% ... +15%
Rated conditional short-circuit current 100 A
Current consumption
Guard locking inactive 80 mA
Guard locking active 350 mA
Control input I_IMP min.20 mA
Fusing
External (operating voltage UB) 1 A
Rated insulation voltage Ui max.30 V
Rated impulse withstand voltage Uimp max.0,5 kV
EMC protection requirements In acc. with EN 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Monitoring output OT 700 ... 2500 ms
Safety outputs 700 ... 2500 ms
Safety class III
Discrepancy time max.10 ms
Risk time according to EN 60947-5-3 max.260 ms
Delay per device 5 ms
FO1A/FO1B
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching frequency, electrical 0,5 Hz
Switching current
Per output 1 ... 150 mA
Output voltage
HIGH U(FO1A) / U(FO1B) UB - 1,5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Utilization category according to EN 60947-5-2
DC-13 DC-13 24V 150mA
Off-state current Ir max.0,25 mA
OT, OI, OL
Type of output Semiconductor output, p-switching, short circuit-proof
Switching current
Per monitoring output max.50 mA
Output voltage 0,8 x UB ... UB V DC
Work area
Assured switch-off distance Sar 18 mm
Center offset -5 ... +5 mm
Reliability values according to EN ISO 13849-1
Monitoring of the position of the safety guard
Category 4
Performance Level PL e
PFHD 4.5 x 10-9
Mission time 20 y

Explore the CEM-I2-AR-U-C40-SH-124937 124937 industrial spare part, meticulously engineered for performance and reliability. This industrial spare part is crucial for ensuring your machinery operates smoothly and efficiently. With CEM-I2-AR-U-C40-SH-124937 124937, you receive top-notch industrial spare parts designed for durability and optimal function.

The CEM-I2-AR-U-C40-SH-124937 124937 replacement component ensures that your machinery will operate more efficiently, cutting downtime and preserving output. These replacement components provide unmatched durability and dependability since they are made to endure the demands of industrial operation. You may quickly get the parts you need by ordering your CEM-I2-AR-U-C40-SH-124937 124937 spare part online and having it delivered to you.

A comprehensive selection of industrial spare parts suitable for different models and applications is provided by Euchner. In order to keep your equipment operating at peak efficiency, Euchner offers high-quality replacement parts that can be used for maintenance or to replace worn-out components.

You may rely on Euchner as your reliable supplier for high-performance industrial spare parts. To get the necessary spare parts, place an online order or stop by our store. You can invest in efficiency and quality for your industrial machines by using CEM-I2-AR-U-C40-SH-124937 124937. Our industrial spare parts are made to the highest specifications and provide dependable solutions for all of your equipment requirements.

Euchner ensures that you find the right spare parts next to you or available online. Order now and experience the difference in equipment performance with Euchner CEM-I2-AR-U-C40-SH-124937 124937. Invest in industrial spare parts that provide dependable service and keep your operations running smoothly.

Delivery terms

We offer convenient and flexible delivery terms to all our customers. No matter where you are, we will ensure fast and reliable delivery of your order.

Basic delivery conditions:

  • Geography of delivery: We deliver throughout UK. Regardless of your location, you can be sure that your order will be delivered as quickly as possible.
  • Delivery time: delivery time depends on your location and the delivery method you choose. We offer various options, including express shipping, to make sure you receive your order as quickly as possible.
  • Delivery costs: Delivery costs are calculated individually depending on the weight, dimensions of the goods and the destination. We are committed to offering our customers competitive shipping prices.
  • Delivery methods: We work with leading logistics companies to ensure safe and timely delivery. You can choose the delivery method that is most convenient for you.
  • Order tracking: once your order has been placed, you will receive a tracking number so that you can know the status and location of your order at any time.
  • Additional services: we also offer insurance and packaging services to make sure your item arrives safely.
Important information:
- Please provide an accurate delivery address when placing your order to avoid delays and delivery errors.
- Please note that customs duties and taxes on the destination country may apply depending on the situation. These costs are not included in the cost of the goods and delivery and must be paid separately.

We make every effort to make the delivery process as convenient and fast as possible for you. If you have any questions or need additional information, our support team is always ready to help you.