Home Brands Euchner 114088 CET3-AR-CRA-AH-50X-SH-C2290-114088

Euchner CET3-AR-CRA-AH-50X-SH-C2290-114088 114088

 CET3-AR-CRA-AH-50X-SH-C2290-114088 Euchner 114088
Sale of Euchner products with worldwide delivery. We have a complete catalog of products of this brand. If you didn’t find something on the site, leave a request. The manager will call you back and help. Our current product range covers more than 90 percent of your needs, no matter what sector you are from (automotive, financial services, chemicals, pharmaceuticals or mechanical engineering, ...)

Competitive Prices
Competitive Prices
Lowest prices among our industrial parts reseller competitors
Extensive Product Range
Extensive Product Range
Thousands of industrial components and numerous suppliers
Swift Delivery
Swift Delivery
Reliable delivery of industrial spare parts worldwide
Sale of any product from the catalog Euchner
Brand
Euchner
Model
CET3-AR-CRA-AH-50X-SH-C2290-114088
Article
114088
Country
Germany
  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • Plug connector M23 (RC18)
  • Unicode
  • Door monitoring output
  • Teach-in input
  • Wire front release (bowden), 5 m, automatic return
  • Approach direction A (default setting on delivery)
Approach direction Horizontal Can be adjusted in 90° steps Safety switchThe device may be operated only in conjunction with the actuator CET-A-.... Important: The actuator must be ordered separately. Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Solenoid operating voltage
  • DC 24 V +10% -15%
Guard locking type
CET3Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.
LED function display
LED StateStatus LED
LED DIADiagnostic LED
LED 1 rdfreely configurable
LED 2 gnfreely configurable
Additional connections
OUTMonitoring output (semiconductor)
OUT DDoor monitoring output
RSTReset input
JTeach-in input
Category according to EN ISO 13849-1Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN ISO 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. The category is dependent on the installation position of the safety switch: Wire front release (bowden)The wire front release permits remote unlocking of the guard locking via a pull wire. Flexible routing of the pull wire permits release of the guard locking in inaccessible installation situations. Important: The wire front release (bowden) is not a safety function.
Housing material
Slide Stainless steel
Safety switch housing Die-cast aluminum
Weight
Net 1 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP65/IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mechanical life 1 x 106
Installation orientation Any
Degree of freedom
Z ±4 mm
Y ±5 mm
X ±5 mm
Ready delay 10 s
Switching frequency max.0,5 Hz
Connection 1 plug connector M23, 19-pin, RC18
Approach speed 20 m/min
Guard locking principle Closed-circuit current principle
Locking force Fmax 6500 N
Locking force FZh 5000 N FZH = FMAX/1.3
Electrical connection ratings
Operating voltage DC
UB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
LED 24 V DC -15% ... 10%
Current consumption
IB 80 mA
ICM 480 mA
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Solenoid operating voltage DC
UCM 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Fusing
External (operating voltage UB) 0,25 ... 8 A
External (solenoid operating voltage UCM) 0,5 ... 8 A
Power consumption
Solenoid max.12 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable 30V DC, 2A
Safety class
EN IEC 61140 III
Switching load
According to UL 24V DC, class 2
Safety outputs OA/OB
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output OA / OB 1 ... 200 mA
Output voltage
High U(OA) / U(OB) UB-1,5V ... UB V DC
Low U(OA) / U(OB) 0 ... 1 V DC
Off-state current Ir max.0,25 mA
Risk time according to EN 60947-5-3
Delay per device 5 ms
Single device max.400 ms
Switch-on time 400 ms
Discrepancy time
Both safety outputs max.10 ms
Monitoring output OUT
Type of output p-switching, short circuit-proof
Switching current
OUT 1 ... 50 mA
Output voltage
OUT 0,8xUB ... UB V DC
Switching delay from state change max.400 ms
Monitoring output OUT D
Type of output p-switching, short circuit-proof
Switching current
OUT D 1 ... 50 mA
Output voltage
OUT D 0,8xUB ... UB V DC
Switching delay from state change max.700 ms
Teach-in input
Input voltage
High 15 ... 27,6 V DC
Low 0 ... 1 V DC
Work area
Repeat accuracy R 10 %
Other
C number
C2290 With wire front release (bowden) mounted
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
Category
Head upward 3
Head downward or horizontal 4
Performance Level PL e
PFHD
Head downward or horizontal 3.1 x 10-9
Head upward 4.29 x 10-8
Control of the guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
Mission time 20 y

Explore the CET3-AR-CRA-AH-50X-SH-C2290-114088 114088 industrial spare part, meticulously engineered for performance and reliability. This industrial spare part is crucial for ensuring your machinery operates smoothly and efficiently. With CET3-AR-CRA-AH-50X-SH-C2290-114088 114088, you receive top-notch industrial spare parts designed for durability and optimal function.

The CET3-AR-CRA-AH-50X-SH-C2290-114088 114088 replacement component ensures that your machinery will operate more efficiently, cutting downtime and preserving output. These replacement components provide unmatched durability and dependability since they are made to endure the demands of industrial operation. You may quickly get the parts you need by ordering your CET3-AR-CRA-AH-50X-SH-C2290-114088 114088 spare part online and having it delivered to you.

A comprehensive selection of industrial spare parts suitable for different models and applications is provided by Euchner. In order to keep your equipment operating at peak efficiency, Euchner offers high-quality replacement parts that can be used for maintenance or to replace worn-out components.

You may rely on Euchner as your reliable supplier for high-performance industrial spare parts. To get the necessary spare parts, place an online order or stop by our store. You can invest in efficiency and quality for your industrial machines by using CET3-AR-CRA-AH-50X-SH-C2290-114088 114088. Our industrial spare parts are made to the highest specifications and provide dependable solutions for all of your equipment requirements.

Euchner ensures that you find the right spare parts next to you or available online. Order now and experience the difference in equipment performance with Euchner CET3-AR-CRA-AH-50X-SH-C2290-114088 114088. Invest in industrial spare parts that provide dependable service and keep your operations running smoothly.

Delivery terms

We offer convenient and flexible delivery terms to all our customers. No matter where you are, we will ensure fast and reliable delivery of your order.

Basic delivery conditions:

  • Geography of delivery: We deliver throughout UK. Regardless of your location, you can be sure that your order will be delivered as quickly as possible.
  • Delivery time: delivery time depends on your location and the delivery method you choose. We offer various options, including express shipping, to make sure you receive your order as quickly as possible.
  • Delivery costs: Delivery costs are calculated individually depending on the weight, dimensions of the goods and the destination. We are committed to offering our customers competitive shipping prices.
  • Delivery methods: We work with leading logistics companies to ensure safe and timely delivery. You can choose the delivery method that is most convenient for you.
  • Order tracking: once your order has been placed, you will receive a tracking number so that you can know the status and location of your order at any time.
  • Additional services: we also offer insurance and packaging services to make sure your item arrives safely.
Important information:
- Please provide an accurate delivery address when placing your order to avoid delays and delivery errors.
- Please note that customs duties and taxes on the destination country may apply depending on the situation. These costs are not included in the cost of the goods and delivery and must be paid separately.

We make every effort to make the delivery process as convenient and fast as possible for you. If you have any questions or need additional information, our support team is always ready to help you.