Sale of Euchner products with worldwide delivery. We have a complete catalog of products of this brand. If you didn’t find something on the site, leave a request. The manager will call you back and help. Our current product range covers more than 90 percent of your needs, no matter what sector you are from (automotive, financial services, chemicals, pharmaceuticals or mechanical engineering, ...)

Competitive Prices
Competitive Prices
Lowest prices among our industrial parts reseller competitors
Extensive Product Range
Extensive Product Range
Thousands of industrial components and numerous suppliers
Swift Delivery
Swift Delivery
Reliable delivery of industrial spare parts worldwide
Sale of any product from the catalog Euchner
Brand
Euchner
Model
CES-AR-AES-12
Article
098225
Country
Germany
  • Central evaluation of an AR switch chain
  • Status of each individual switch can be seen
  • For switch chains of up to 12 devices
  • Four individual safe relay contacts
  • Category 4/PLe according to EN ISO 13849-1
Important: A switch chain comprising the following switches can be connected to the AR evaluation unit: CES-AR-C01 / CES-AR-C02 / CES AR-C04 / ESL-AR / CET- AR / CTP-AR FunctionThe AR evaluation unit is used to evaluate the individual safety switches in a CES-AR-... switch chain and the safe interruption of a safety circuit. The unit has two inputs for connection of a CES-AR... switch chain. The safety contacts are switched as a function of the input signals. Downstream parts of the safety circuit can be monitored using a feedback loop. The switching states of the connected safety switches can be signaled by means of monitoring outputs. If the actuator on one of the safety switches in the switch chain is moved out of the operating distance, the AR evaluation unit opens its contacts and the corresponding monitoring output is reset. The system is designed so that failures will not result in the loss of the safety function. The occurrence of failures is detected by cyclic self-monitoring at the latest at the next demand to close the safety contacts. The system can be started either manually using a start button or automatically. Category according to EN ISO 13849-1Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:
  • Category 4/PL e according to EN ISO 13849-1
Each safety path is independently safe. LED indicator
STATEStatus LED
DIADiagnostics LED
OUTSafe state/self-test
Important:The plug-in connection terminals are not included and must be ordered separately. Dimension drawing Wiring diagram Wiring diagram Dimension drawingWiring diagramWiring diagram Technical dataApprovals Mechanical values and environment
Dimensions 114 x 99 x 45
Housing material Plastic PA6.6
Weight
Net 0,25 kg
Ambient temperature
At UB = DC 24 V -20 ... 55 °C
Atmospheric humidity
Not condensing max.80 % rH
Degree of protection IP20
Resilience to vibration In acc. with EN 60947-5-2
Mounting method Mounting rail 35 mm according to EN 60715
Ready delay max.8 s
Connection Plug-in screw terminals coded
Number of LED displays 3
O1 ... O12
Number of monitoring outputs 12
Start button S
Manual start operating mode
Response delay start button 300 ... 600 ms
Duration of operation of start button min.250 ms
13/14, 23/24, 33/34, 43/44
Number of safety contacts 4 Relays with internally monitored contacts
Mechanical life
Relay 10 x 106
Switching frequency 1 Hz 100 mA, a switching frequency of 0.1 Hz should not be exceeded as this will affect the mechanical life of the relay contacts.'>
Electrical connection ratings
Operating voltage DC
UB 24 V DC -10% ... 10% Regulated, residual ripple < 5 %
Current consumption
IB (with relay energized) 1200 mA
Fusing
External (operating voltage UB) 2,5 ... 8 A
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 4 kV
EMC protection requirements In acc. with EN 60947-5-3
Degree of contamination (external, according to EN 60947-1) 2
Connection cross-section 0,14 ... 2,5 mm?
Switching delay from state change max.480 ms
STATE
LED indicator
STATE Green LED: Status of the device
OUT
LED indicator
OUT Yellow LED: State of the AR chain
IA, IB
Number of connectible safety switches max.12
Safety inputs 2 (for CES-AR switch chain)
13/14, 23/24, 33/34, 43/44
Switching current
Relay outputs (at switching voltage AC 5 ... 230 V) 10 ... 5000 mA
Relay outputs (at switching voltage AC/DC 21 ... 60 V 1 ... 300 mA
Relay outputs (at switching voltage AC/DC 5 ... 30 V) 10 ... 6000 mA
Fusing
External (safety circuit) according to EN 60269-1 6 AgG or 6 A circuit breaker (characteristic B or C)
Utilization category according to EN 60947-5-1
AC-15 230 V 5 A
DC-13 24 V 5 A
AC-12 60 V 0.3 A
30 V 6 A
DC-12 30 V 6 A
60 V 0.3 A
Discrepancy time
Between the operating points of both relays max.25 ms
Start button S
Input current
HIGH 5 ... 8 ... 10 mA
Input voltage
HIGH 15 ... UB V DC
LOW 0 ... 2 V DC
Y1/Y2
Current via feedback loop 5 ... 8 ... 10 mA
permissible resistance in feedback loop max.600 ?
DIA
LED indicator
DIA Red LED: Fault display
Type of output Semiconductor output, p-switching, short circuit-proof
Output voltage
HIGH UB - 20% ... UB V DC
LOW 0 ... 1 V DC
Output current max.20 mA
O1 ... O12
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW 0 ... 1 V DC
High UB - 20% ... UB V DC
Output current max.20 mA
OUT AR
Type of output Semiconductor output, p-switching, short circuit-proof
Output voltage
HIGH UB - 20 % ... UB V DC
LOW 0 ... 1 V DC
Output current max.20 mA
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 1.5 x 10-8
Number of switching cycles
? 3 A at 24 V DC max.107000 1/Jahr
? 1 A at 24 V DC max.540000 1/Jahr
? 0.1 A at 24 V DC max.720000 1/Jahr
Mission time 20 y

Explore the CES-AR-AES-12 098225 industrial spare part, meticulously engineered for performance and reliability. This industrial spare part is crucial for ensuring your machinery operates smoothly and efficiently. With CES-AR-AES-12 098225, you receive top-notch industrial spare parts designed for durability and optimal function.

The CES-AR-AES-12 098225 replacement component ensures that your machinery will operate more efficiently, cutting downtime and preserving output. These replacement components provide unmatched durability and dependability since they are made to endure the demands of industrial operation. You may quickly get the parts you need by ordering your CES-AR-AES-12 098225 spare part online and having it delivered to you.

A comprehensive selection of industrial spare parts suitable for different models and applications is provided by Euchner. In order to keep your equipment operating at peak efficiency, Euchner offers high-quality replacement parts that can be used for maintenance or to replace worn-out components.

You may rely on Euchner as your reliable supplier for high-performance industrial spare parts. To get the necessary spare parts, place an online order or stop by our store. You can invest in efficiency and quality for your industrial machines by using CES-AR-AES-12 098225. Our industrial spare parts are made to the highest specifications and provide dependable solutions for all of your equipment requirements.

Euchner ensures that you find the right spare parts next to you or available online. Order now and experience the difference in equipment performance with Euchner CES-AR-AES-12 098225. Invest in industrial spare parts that provide dependable service and keep your operations running smoothly.

Delivery terms

We offer convenient and flexible delivery terms to all our customers. No matter where you are, we will ensure fast and reliable delivery of your order.

Basic delivery conditions:

  • Geography of delivery: We deliver throughout UK. Regardless of your location, you can be sure that your order will be delivered as quickly as possible.
  • Delivery time: delivery time depends on your location and the delivery method you choose. We offer various options, including express shipping, to make sure you receive your order as quickly as possible.
  • Delivery costs: Delivery costs are calculated individually depending on the weight, dimensions of the goods and the destination. We are committed to offering our customers competitive shipping prices.
  • Delivery methods: We work with leading logistics companies to ensure safe and timely delivery. You can choose the delivery method that is most convenient for you.
  • Order tracking: once your order has been placed, you will receive a tracking number so that you can know the status and location of your order at any time.
  • Additional services: we also offer insurance and packaging services to make sure your item arrives safely.
Important information:
- Please provide an accurate delivery address when placing your order to avoid delays and delivery errors.
- Please note that customs duties and taxes on the destination country may apply depending on the situation. These costs are not included in the cost of the goods and delivery and must be paid separately.

We make every effort to make the delivery process as convenient and fast as possible for you. If you have any questions or need additional information, our support team is always ready to help you.